Control Method:2-way, 3-port, proportional control
Power off:fuel flows from port A to port T
Power on:fuel flows from port P to port A
When port A pressure exceeds MAX.pressure, fuel spills from port T
Application:Switch/directional control device
KD-5K31/G24DA40
Control Method:2-way, 3-port, proportional control
Power off:fuel flows from port A to port T
Power on:fuel flows from port P to port A
When port A pressure exceeds MAX.pressure, fuel spills from port T
Application:Switch/directional control device
Working Voltage: | DC24V |
Working Current: | Nominal Voltage 85%~115%(24V) |
Drive Frequency: | 80~100Hz(Current/Voltage Control) |
Maximum Flow: | 16L/min |
Maximum Fuel Supply Pressure: | P=8.8Mpa |
Maximum Back Pressure: | T=1Mpa |
Coil: | 24V(Environment Temperature 25℃) |
Response Time: | T open ≤50ms;T close ≤50ms |
Pressure Characteristics: | see ” Functional Chart”(The test data is P port pressure 50bar) |
Internal Leakage(Power off): | <50ml/min |
Usage Environment Temperature: | -30℃ to 90℃ |
Usage Medium Temperature: | -30℃ to 120℃ |
Usage Medium Viscosity Range: | 5~500cSt mineral oil or lubricating synthetic oil |
Installation: | Bolts fastening,tightening torque 7±1Nm |
IP Functions: | IP69K |
Protective Properties: | Waterproof, Anti-corrosion |
Ordering Code
KD-5K31/G24DA40 | 91003 |